• Description of solid-liquid and vapour-liquid phase equilibrium curve for organic and organometallic compounds (experimental determination of vapour pressure, simultaneous correlation of vapour pressure and of related thermal properties). Details.

 

• Calorimetric determination of heat capacities and of phase change enthalpies. Heat capacity of liquids: compilation, correlation, and prediction (database of experimental heat capacities of liquids, database of critically evaluated data, group contribution method). Enthalpy of vaporization: compilation, prediction.

 

• Computational chemistry.

 

Equipment

Static Apparatuses for Vapour Pressure Measurement

Several versions of static apparatuses were designed and constructed in our group.  The apparatuses internally denoted as STAT3, STAT6 and STAT7 are currently in use. The construction of STAT8 is in progress. All the apparatuses are fully automated.

STAT 3 apparatus

STAT 3 apparatus

Temperature range: from  40 °C to 200 °C

- Pt100 resistance thermometer

- accuracy better than 0.02 K

- four wire connection

- calibrated to ITS-90 (NIST traceable)

Pressure range: from 0.8 Pa to 13332 Pa (100 Torr)

- MKS Baratron, type 616A12TRC

- differential type

- accuracy 0.12% of reading

STAT 6 apparatus

STAT6 apparatus

Temperature range: from - 40 °C to 40 °C

- Pt100 resistance thermometer

- accuracy better than 0.02 K

- four wire connection

- calibrated to ITS-90 (NIST traceable)

Pressure range: from 0.1 Pa to 1333 Pa (10 Torr)

- MKS Baratron, type 690A11TRA and 690A01TRA

- accuracy 0.05% of reading

- transfer standards (NIST traceable)

 

Reference vapour pressure data for naphthalene were obtained using this apparatus (see our publication Růžička, K.; Fulem, M.; Růžička, V. J. Chem. Eng. Data 2005, 50, 1956 and CRC Handbook of Chemistry and Physics (88 edition, 2007-2008) ).

STAT 7 apparatus (Institute of Physics)

STAT7 apparatus

Temperature range: from - 20 °C to 45 °C

- Pt100 resistance thermometer

- accuracy better than 0.02 K

- four wire connection

- calibrated to ITS-90 (NIST traceable)

Pressure range: from 1 Pa to 13332 Pa (100 Torr)

- MKS Baratron, type 631A12TBEM

- accuracy 0.12% of reading

- differential type

SUITABLE ALSO FOR TOXIC MATERIALS

Decomposition furnace working at 800°C

Dry scrubber

Calorimeters

SETARAM Micro DSC III

SETARAM Micro DSC III

TA Q1000

TA Q1000

Leak detector

MKS Pico

MKS Pico Vacuum Helium Leak Detector